Installation of Flange Mountings on CSVF-500 Vacuum Capacitor
Purpose:
-
To provide instructions for the installation of the flange mountings
on the CSVF-500 vacuum capacitor.
-
To provide a recommendation for torque rating on the clamping screws
of the FM2S and FM2 flange mountings. Proper clamping will ensure secure
mount of the capacitor to the system and alleviate potential capacitor
damage due to over tightening.
Procedure:
-
Place FM2 mounting flange (P/N 110954) onto variable end of capacitor
with mounting holes furthest away from body of capacitor as shown in Figure
2. Make sure mounting flange is firmly seated against variable end seal.
Caution: Do not force flange mounting onto capacitor. Make sure
clamping screw is fully loosened so the flange mounting slips freely over
variable end seal of capacitor.
-
Hand tighten flange screw up to 6.0 to 6.5 in-lbs.
-
Check to make sure that flange mounting is secure on capacitor.
Figure 2
Figure 3
Fixed End Flange Mounting
-
Place FM2S mounting flange (P/N 101959) onto fixed end of capacitor
with mounting holes furthest away from body of capacitor as shown
in Figure 3. Make sure mounting flange is firmly seated against
fixed end seal.
Caution: Do not force flange mounting onto capacitor. Make
sure both clamping screws are fully loosened so the flange mounting
slips freely over fixed end seal of capacitor.
-
Tighten clamping screw (A) on flange mounting until resistance
is felt (Do not exceed 2.0 in-lbs torque). Repeat process for clamping
screw (B) (See Figure 3).
-
Apply 3.5 to 4.0 in-lbs of torque to first screw (A), then apply
3.5 to 4.0 in-lbs of torque to second screw (B) (See Figure 3).
-
Check to make sure that flange mounting is secure on the capacitor.
|